GENTAUR
+32 1658 9045
or
0032 (0)16 41 44 07
+32 1650 9045
[email protected]
Av. de l' Armée 68
B-1040 Brussels
BELGIUM
France
tel 01 43 25 01 50
fax01 43 25 01 60
9, rue Lagrange
75005 Paris
Italia
tel 02 36 00 65 93
fax 02 36 00 65 94
20135 Milano
Deutschland
tel +32 1658 9045
fax +32 1650 9045
Polska
Tel 058 710 33 44
Fax 00 32 16 50 90 45
ul. Grunwaldzka 88A/2
81-771 Sopot
日本
tel +81 78 386 0860
fax +81 78 306 0296
Minaatojimaminami-manchi
Chuo-ku, Kobe
065-0047
Österreich
+43720880899
Canada Montreal
+15149077481
Česká republika Praha
+420246019719
Danmark
+4569918806
Finland Helsset
+358942419041
Ελλάς Αθήνα
+302111768494
Magyarország Budapest
+3619980547
Ireland Dublin
+35316526556
Luxembourg
+35220880274
Nederland
+31208080893
Norge Oslo
+4721031366
Polska Warszawa
+48223988221
Sverige Stockholm
+46852503438
Schweiz Züri
+41435006251
US New York
+17185132983
Other Countries
0032 (0)16 41 44 07
|
|
| |
Co2
Incubator
----------------------------------------Intelligentized
microprocessor control |
|
|
Summary: |
CO2
incubator is not only an
advanced instrument for
cultivation of cells,
tissues and bacteria,
but also
a
key equipment for
immunology, oncology,
genetics and
bioengineering. It is
widely applicable for
research and production
of microorganisms,
agricultural science and
pharmacology. |
|
Features: |
1.
Customized design,
micro-processor control,
stainless-steel chamber,
semicircular arcs at
corners for easy
cleaning. |
2. Can
sterilize circulatory
air and the cell in
humid tray by
Ultraviolet Lamp which
locate the back of box.
|
3.
Equipped with
microorganism HEPA
Filter, can filter the
atomy larger than 0.3
um, filter efficiency
more than 99.99%. |
4.
Glass-door warm system
can heat up the inner
door, avoid the
condensed water produce
that reduce the possible
of Microbial
Contamination. |
5. With
circulating fan speed
auto-control system,
avoid the volatilization
of sample when the fan
speed is too fast. |
6.
Independent alarm system
for temperature-limiting
ensures experiments run
safely and no accident
would happen. |
7.
Over-temperature warning
and alarm. |
8. Door
open time too long
alarm. |
|
Option: |
1.
Humidity Display |
2. CO2
pressure-releasing valve |
3.
RS-485 connector and
communication software.
|
|
|
Specifications: |
Model |
BPN-80CH(UV) |
BPN-150CH(UV) |
BPN-80CW(UV) |
BPN-150CW(UV) |
Electrical
Requirements |
220V 50HZ |
Input Power |
500W |
750W |
680W |
950W |
Heating Method
|
Air-jacketed |
Water-jacketed |
Temperature
Range |
RT+5 ~ 50oC |
Temperature
Control |
0.1oC |
Temperature
Stability |
+/- 0.3oC |
+/- 0.1oC
|
CO2
Range |
0~20%(air-adjusting
type) |
CO2
Recovery |
<=Calibration*1.2min |
Humidifying
Method |
Natural
evaporization |
Ambient
temperature |
+5~35oC |
Cubage |
80L |
155L |
80L |
155L |
Interior
Dimension
(mm)W*D*H
|
400*400*500 |
530*480*610 |
400*400*500 |
530*480*610
|
Overall
Dimension
(mm)W*D*H
|
580*500*690 |
650*630*800 |
580*500*690
|
690*630*800
|
Shelves per
Chamber(Normal) |
2(pcs) |
3(pcs) |
2(pcs) |
3(pcs) |
|
|
※ Specification
test under no load
condition:ambienttemperature
20 oC,and
relative humidity50%. |
|
Co2
Incubator
---------------------------------------Special
for cell culture |
|
Summary: |
CO2
incubator is not only an
advanced instrument for
cultivation of cells,
tissues and bacteria,
but also
a
key equipment for
immunology, oncology,
genetics and
bioengineering. It is
widely applicable for
research and production
of microorganisms,
agricultural science and
pharmacology. |
|
Features: |
1. More quickly Co2
concentration recover
time. Equipped with
high-precision Co2
sensor, can quickly
recover Co2
concentration, if closed
door after 30 senconds,
it can recover to 37
oC within 10
minutes and recover to
5% Co2 within 5 minutes.
|
2. Can sterilize
circulatory air and the
cell in humid tray by
Ultraviolet Lamp which
locate the back of box.
|
3. Equipped with
microorganism HEPA
Filter, can filter the
atomy larger than 0.3
um, filter efficiency
more than 99.99%. |
4. Glass-door warm
system can heat up the
inner door, avoid the
condensed water produce
that reduce the possible
of Microbial
Contamination. |
5. With circulating
fan speed auto-control
system, avoid the
volatilization of sample
when the fan speed is
too fast. |
6. Independent alarm
system for
temperature-limiting
ensures experiments run
safely and no accident
would happen. |
7. Over-temperature
& over Co2 concentration
warning and alarm.
|
8. Door open time
too long alarm. |
9. Gaint-screen LCD
& micro-processor PID
control, can dispaly
temprature, Co2
concentration & humidity
at one time |
|
|
Specifications: |
Model |
BPN-80RH(UV) |
BPN-150RH(UV) |
BPN-240CW(UV) |
Electrical
Requirements |
220V 50HZ |
Input Power |
500W |
750W |
950W |
Heating Method
|
Air-jacketed
micro-processor
PID control |
Temperature
Range |
RT+5 ~ 50oC |
Working
environment
Temperature
Range
|
RT+5 ~ 30oC
|
Temperature
Stability |
+/- 0.1oC |
CO2
Range |
0~20% |
CO2
Precision
|
+/- 0.1%
(Infrared
Sensor)
|
CO2
Recovery |
<=3 min(After
door open 30
seconds recover
to 5%) |
Temperature
Recovery
|
<=8
min(After
door open 30
seconds
recover 37oC)
|
Humidifying
Method |
Natural
evaporization |
|
|
Ambient
temperature |
+5~35oC |
|
|
Cubage |
80L |
155L |
155L |
Interior
Dimension
(mm)W*D*H
|
400*400*500 |
530*480*610 |
530*480*610
|
Overall
Dimension
(mm)W*D*H
|
580*500*690 |
650*630*800 |
690*630*800
|
Shelves per
Chamber(Normal) |
2(pcs) |
3(pcs) |
3(pcs) |
|
|
※ Specification
test under no load
condition:ambienttemperature
20 oC,and
relative humidity50%. |
|
|
|
|
|
|
|