GENTAUR
+32 1658 9045
or
0032 (0)16 41 44 07
+32 1650 9045
[email protected]
Av. de l' Armée 68
B-1040 Brussels
BELGIUM
France
tel 01 43 25 01 50
fax01 43 25 01 60
9, rue Lagrange
75005 Paris
Italia
tel 02 36 00 65 93
fax 02 36 00 65 94
20135 Milano
Deutschland
tel +32 1658 9045
fax +32 1650 9045
Polska
Tel 058 710 33 44
Fax 00 32 16 50 90 45
ul. Grunwaldzka 88A/2
81-771 Sopot
日本
tel +81 78 386 0860
fax +81 78 306 0296
Minaatojimaminami-manchi
Chuo-ku, Kobe
065-0047
Österreich
+43720880899
Canada Montreal
+15149077481
Česká republika Praha
+420246019719
Danmark
+4569918806
Finland Helsset
+358942419041
Ελλάς Αθήνα
+302111768494
Magyarország Budapest
+3619980547
Ireland Dublin
+35316526556
Luxembourg
+35220880274
Nederland
+31208080893
Norge Oslo
+4721031366
Polska Warszawa
+48223988221
Sverige Stockholm
+46852503438
Schweiz Züri
+41435006251
US New York
+17185132983
Other Countries
0032 (0)16 41 44 07
|
|
| |
|
C860
basic multi-parameter analyser for pH,
mV, conductivity, Salinity, TDS and temperature |
|
1
pH/mV channel
1 conductivity channel
1 temperature channel
A high resolution graphic screen with white
backlight shows measurements and temperature.
Full guidance is given by simple instructions on the display in the
language of your choice (English, Dutch, French, German).
Storage memory for 300 measurements.
Shows a GLP report on the screen.
Three year warranty
Robust dust and splash-proof cabinet.
Operates on the mains (120/230 VAC) or 9...15 VDC.
Optional 12 V car adaptor permits these laboratory meters to work in a
car.
Specifications
pH: 0...14 pH
mV: ± 1000 mV
Conductivity: 0...100 mS/cm
Salinity: 0...70 ppt TDS: 0...100
g/l
Temperature: 0...100°C
Resolution: 0.01 pH, 1 mV,
0.1µS/cm, 1°C |
|
download leaflet |
download manual | |
|
|
C861
multi-parameter analyser for pH, mV, conductivity,
resistivity, salinity, TDS and temperature |
|
2 pH/mV
channels
1 conductivity channel
1 temperature channel
A high resolution graphic screen with white
backlight indicates all measurements and operating parameters such as
temperature, date and time.
Multi-point (1...5) calibration of pH electrodes with any of nine
pre-programmed and five user specified standards.
Multi-point (1...3) calibration of conductivity electrodes for increased
linearity with any of three pre-programmed or user specified standards.
The display guides you at any moment in the language of your choice
(English, Dutch, French, German).
All necessary GLP-procedures are on board.
Password protection prevents any unauthorised access to the instrument.
Three year warranty.
Storage memory for up to 12000 values + date and time.
Programmable recorder output.
Two-way communication with any computer using USB.
Robust dust and splash-proof cabinet.
Operates on the mains (120/230 VAC) or 9...15 VDC.
Optional 12 V car adaptor permits these laboratory meters to work in a
car.
Optional data acquisition software enables to view, store and edit the
measurements in your computer.
Specifications
pH: -2...+16 pH
mV: ± 2000 mV
Conductivity: 0...2000 mS/cm
Resistivity: 0...200 Mohm.cm
Salinity: 0...70 ppt TDS: 0...100 g/l
Temperature: -30...+130°C
Resolution: 0.001 pH, 0.1 mV, 0.001µS/cm, 1
ohm.cm, 0.01 mg/l, 0.1 ppt, 0.1°C |
|
download leaflet |
download manual | |
|
|
C862
multi-parameter analyser for pH, mV,
conductivity, resistivity, salinity, TDS, dissolved oxygen and
temperature |
|
2 pH/mV channels
1 conductivity channel
1 oxygen channel
1 temperature channel
A high resolution graphic screen with white
backlight indicates all measurements and operating parameters such as
temperature, date and time.
Multi-point (1...5) calibration of pH electrodes with any of nine
pre-programmed and five user specified standards.
Multi-point (1...3) calibration of conductivity electrodes for increased
linearity with any of three pre-programmed or user specified standards.
The display guides you at any moment in the language of your choice
(English, Dutch, French, German).
All necessary GLP-procedures are on board.
Operates with a galvanic oxygen electrode requiring no polarisation
time.
Password protection prevents any unauthorised access to the instrument.
Three year warranty.
Storage memory for up to 12000 values + date and time.
Programmable recorder output.
Two-way communication with any computer using USB or RS232.
Robust dust and splash-proof cabinet.
Operates on the mains (120/230 VAC) or 9...15 VDC.
Optional 12 V car adaptor permits these laboratory meters to work in a
car.
Optional data acquisition software enables to view, store and edit the
measurements in your computer.
Specifications
pH: -2...+16 pH
mV: ± 2000 mV
Conductivity: 0...2000 mS/cm
Resistivity: 0...200 Mohm.cm
Salinity: 0...70 ppt
TDS: 0...100 g/l
Dissolved oxygen: 0...60mg/l, 0...600 %
Air pressure: 800...1100 hPa
Temperature: -30...+130°C
Resolution: 0.001 pH, 0.1 mV, 0.001µS/cm, 1 ohm.cm, 0.01 mg/l,
0.1 ppt, 0.1°C |
|
download leaflet |
download manual | |
|
|
C863
multi-parameter analyser for pH, ion, mV,
conductivity, resistivity, salinity, TDS, oxygen and temperature |
|
2 pH/mV/ion
channels
1 conductivity channel
1 oxygen channel
1 temperature channel
A high resolution graphic screen with white
backlight indicates all measurements and operating parameters such as
temperature, date and time.
Multi-point (1...5) calibration of pH electrodes with any of nine
pre-programmed and five user specified standards.
Multi-point (1...3) calibration of conductivity electrodes for increased
linearity with any of three pre-programmed or user specified standards.
Two-point calibration + blank correction of ion-selective electrodes.
The display guides you at any moment in the language of your choice
(English, Dutch, French, German).
All necessary GLP-procedures are on board.
Operates with a galvanic oxygen electrode requiring no polarisation
time.
Password protection prevents any unauthorised access to the instrument.
Three year warranty.
Storage memory for up to 12000 values + date and time.
Programmable recorder output.
Two-way communication with any computer using USB or RS232.
Robust dust and splash-proof cabinet.
Operates on the mains (120/230 VAC) or 9...15 VDC.
Optional 12 V car adaptor permits these laboratory meters to work in a
car.
Optional data acquisition software enables to view, store and edit the
measurements in your computer.
Specifications
pH: -2...+16 pH
mV: ± 2000 mV
Ion: 10-11...10+1, any unit
Conductivity: 0...2000 mS/cm
Resistivity: 0...200 Mohm.cm
Salinity: 0...70 ppt
TDS: 0...100 g/l
Dissolved oxygen: 0...60mg/l, 0...600 %
Air pressure: 800...1100 hPa
Temperature: -30...+130°C
Resolution: 0.001 pH, 0.1 mV, 0.001µS/cm, 1
ohm.cm, 0.01 mg/l, 0.1 ppt, 0.1°C |
|
download leaflet |
download manual | |
|
|
C864
multi-parameter analyser for pH, mV, ion,
conductivity, resistivity, salinity, TDS and temperature |
|
6 pH/mV/ion
channels
1 conductivity channel
1 temperature channel
A high resolution graphic screen with white
backlight indicates all measurements and operating parameters such as
temperature, date and time.
Multi-point (1...5) calibration of pH electrodes with any of nine
pre-programmed and five user specified standards.
Multi-point (1...3) calibration of conductivity electrodes for increased
linearity with any of three pre-programmed or user specified standards.
Two-point calibration + blank correction of ion-selective electrodes.
The display guides you at any moment in the language of your choice
(English, Dutch, French, German).
All necessary GLP-procedures are on board.
Password protection prevents any unauthorised access to the instrument.
Three year warranty.
Storage memory for up to 12000 values + date and time.
Programmable recorder output.
Two-way communication with any computer using USB or RS232.
Robust dust and splash-proof cabinet.
Operates on the mains (120/230 VAC) or 9...15 VDC.
Optional 12 V car adaptor permits these laboratory meters to work in a
car.
Optional data acquisition software enables to view, store and edit the
measurements in your computer.
Specifications
pH: -2...+16 pH
mV: ± 2000 mV
Ion: 10-11...10+1, any unit
Conductivity: 0...2000 mS/cm
Resistivity: 0...200 Mohm.cm
Salinity: 0...70 ppt
TDS: 0...100 g/l
Resolution: 0.001 pH, 0.1 mV, 0.001µS/cm, 1 ohm.cm, 0.01 mg/l,
0.1 ppt, 0.1°C |
|
download leaflet |
download manual | |
|
|
C868
BEV analyser for pH, redox, rH2,
conductivity, resistivity, salinity, TDS and temperature |
|
|
download leaflet |
download manual | |
1 pH channel
1 mV channel
1 conductivity channel
1 temperature channel
A high resolution graphic screen with white
backlight indicates all measurements and operating parameters such as
temperature, date and time.
Microprocessor controlled bio-electronic rH2 meter for the study of the
biological water quality or illnesses in body fluids according to
Vincent's method.
Shows mV referred to the standard hydrogen electrode.
Allows simultaneous measurement of all parameters in the same solution.
Calculates the resistance (ohm) and the quantification of Vincent (µW).
Multi-point (1...5) calibration of pH electrodes with any of nine
pre-programmed and five user specified standards.
Multi-point (1...3) calibration of conductivity electrodes for increased
linearity with any of three pre-programmed or user specified standards.
The display guides you at any moment in the language of your choice
(English, Dutch, French, German).
All necessary GLP-procedures are on board.
Password protection prevents any unauthorised access to the instrument.
Three year warranty.
Storage memory for up to 12000 values + date and time.
Programmable recorder output.
Two-way communication with any computer using USB or RS232.
Robust dust and splash-proof cabinet.
Operates on the mains (120/230 VAC) or 9...15 VDC.
Optional 12 V car adaptor permits these laboratory meters to work in a
car.
Optional data acquisition software enables to view, store and edit the
measurements in your computer.
Specifications
pH: 0...14 pH
mV: ± 2000 mV
rH2: 0...42 rH2
Conductivity: 0...2000 mS/cm
Resistivity: 0...200 Mohm.cm
TDS: 0...100 g/l
Salinity: 0...70 ppt
µW: 0...400000 µW
Temperature: 0...100°C
Resolution: 0.001 pH, 0.1 mV, 0.01 rH2, 0.001µS/cm, 1 ohm.cm,
0.01 mg/l, 0.1 ppt, 0.1°C |
|