GENTAUR
+32 1658 9045
or
0032 (0)16 41 44 07
+32 1650 9045
[email protected]
Av. de l' Armée 68
B-1040 Brussels
BELGIUM

France
tel 01 43 25 01 50
fax01 43 25 01 60
9, rue Lagrange
75005 Paris

Italia
tel 02 36 00 65 93
fax 02 36 00 65 94
20135 Milano

Deutschland
tel +32 1658 9045
fax +32 1650 9045

Polska
Tel 058 710 33 44
Fax 00 32 16 50 90 45
ul. Grunwaldzka 88A/2
81-771 Sopot

日本
tel +81 78 386 0860
fax +81 78 306 0296
Minaatojimaminami-manchi
Chuo-ku, Kobe
065-0047


Österreich
+43720880899
Canada Montreal
+15149077481
Česká republika Praha
+420246019719
Danmark
+4569918806
Finland Helsset
+358942419041
Ελλάς Αθήνα
+302111768494
Magyarország Budapest
+3619980547
Ireland Dublin
+35316526556
Luxembourg
+35220880274
Nederland
+31208080893
Norge Oslo
+4721031366
Polska Warszawa
+48223988221
Sverige Stockholm
+46852503438
Schweiz Züri
+41435006251
US New York
+17185132983
Other Countries
0032 (0)16 41 44 07
|
|
| |
|
L1501 Relected Fluorescence Microscope
|
L1501 Reflected fluorescence microscope model is used for
fluorescence microscopy and transmitted bright field microscopy
observation. It is the ideal instrument in sediment in sedimentary rock,
inspection of impurity of semiconductor, environmental protection and
microchemistry etc. It is the ideal instrument in biology, cytology,
oncology, genetics, immunology etc. It also can be used in scientific
research, universities, medical treatment,epidemic prevention etc.
Features:
* With wide field eyepieces and achromatic objectives, the field of view
is widely and clear
* Coaxial coarse/fine focus system, with tensional adjustable and up
stop, minimum division of fine focusing: 2μm
* 6Volt 20Watt Halogen lamp with brightness control |
|
Specification: |
Model |
L1501
|
Eyepiece |
Wide field WF10X(Ř18mm)
|
Objective |
Achromatic 4X/0.10
|
Achromatic 10X/0.25
|
Achromatic 100X/1.25(Spring, oil)
|
Fluorescence 25X/0.65
|
Eyepiece tube |
Trinocular (inclination of 30˚)
|
Focus system |
Coaxial coarse/fine focus, with tension adjustable and up
stop, minimum division of fine focusing: 2μm.
|
Nosepiece |
Quadruple(Backward ball bearing inner locating)
|
Stage |
Double layer mechanical (Size:135mmX125mm, Move range:
75mmX35mm)
|
Abbe condenser |
N.A.1.25 Rack & pinion adjustable
|
Filter |
Blue filter
|
Frosted filter
|
Collector |
For halogen lamp
|
Light source |
6V 20W Halogen lamp with brightness control.
|
Reflected fluorescence system |
Mercury lamp house 100W/DC
|
Power supply unit:AV:110V or 220V
|
Fluorescence filter system B exciton wavelength:420~485nm
|
Fluorescence filter system G exciton wavelength:460~550nm
|
|
|
Optional Accessories: |
Name
|
Sort/Technique parameter
|
Eyepiece |
Wide field WF16X(Ř11mm) |
10X dividing eyepiece 0.1mm/Div |
Objective |
Fluorescence objectives FL 40X/1.00 (Spring,
Glycerin) |
Fluorescence objectives FL 100X/1.25 (Spring,
Glycerin) |
Nosepiece |
Quintuple(Backward ball bearing inner locating) |
Filter |
Green filter |
Yellow filter |
Fluorescence power supply |
100W fluorescence power supply(Wide voltage
range and constant power and calculagraph) |
Reflected fluorescence system |
Fluorescence filter system UV exciton
wavelength:330~400nm |
Fluorescence filter system V exciton
wavelength:395~415nm |
Phase contrast unit |
Eyepiece |
Centering telescope |
Objectives |
Phase contrast plan achromatic 10X/0.25 PHP |
Phase contrast plan achromatic 20X/0.40 PHP |
Phase contrast plan achromatic 40X/0.65 PHP(Spring) |
Phase contrast plan achromatic 100X/1.25 PHP(Spring, oil) |
(PH-1) Turnplate phase contrast condenser |
(PH-2) Turnplate phase contrast condenser |
Flashboard phase contrast condenser |
Pull board phase contrast condenser |
CCD adapter |
0.4X |
0.5X |
1X |
0.5X with dividing 0.1mm/Div |
Camera |
DV-1(With USB & video output) |
DV-2(With USB output) |
DV-3(With video output) |
Digital camera adapter |
CANON digital camera
adapter(A610,A620,A630,A640) |
Photograph unit |
2.5X/4X Change over photograph attachment with
10X viewing eyepiece |
4X Focusing photograph attachment |
MD Adapter |
PK Adapter |
|
|
|