GENTAUR
+32 1658 9045
or
0032 (0)16 41 44 07
+32 1650 9045
[email protected]
Av. de l' Armée 68
B-1040 Brussels
BELGIUM

France
tel 01 43 25 01 50
fax01 43 25 01 60
9, rue Lagrange
75005 Paris

Italia
tel 02 36 00 65 93
fax 02 36 00 65 94
20135 Milano

Deutschland
tel +32 1658 9045
fax +32 1650 9045

Polska
Tel 058 710 33 44
Fax 00 32 16 50 90 45
ul. Grunwaldzka 88A/2
81-771 Sopot

日本
tel +81 78 386 0860
fax +81 78 306 0296
Minaatojimaminami-manchi
Chuo-ku, Kobe
065-0047


Österreich
+43720880899
Canada Montreal
+15149077481
Česká republika Praha
+420246019719
Danmark
+4569918806
Finland Helsset
+358942419041
Ελλάς Αθήνα
+302111768494
Magyarország Budapest
+3619980547
Ireland Dublin
+35316526556
Luxembourg
+35220880274
Nederland
+31208080893
Norge Oslo
+4721031366
Polska Warszawa
+48223988221
Sverige Stockholm
+46852503438
Schweiz Züri
+41435006251
US New York
+17185132983
Other Countries
0032 (0)16 41 44 07
|
|
| |
C561
multi-parameter analyser for pH, mV,
conductivity, salinity, TDS and temperature |
 |
1 pH/mV
channel
1 conductivity channel
1 temperature channel
A high resolution graphic screen with
white backlight shows measurements and temperature.
Full guidance is given by simple instructions on the display in
the language of your choice (English, Dutch, French, German).
Storage memory for 300 measurements.
Shows a GLP report on the screen.
Three year warranty
Robust dust and splash-proof cabinet.
Operates on the mains (120/230 VAC), rechargeable batteries or
9...15 VDC.
Optional 12 V car adaptor permits to work in a car or recharge
the batteries while driving to another site.
Specifications
pH: 0...14 pH
mV: ± 1000 mV
Conductivity: 0...100 mS/cm
Salinity: 0...70 ppt TDS: 0...100
g/l
Temperature: 0...100°C
Resolution: 0.01 pH, 1 mV,
0.1µS/cm, 1°C |
|
|
download leaflet |
download manual | |
|
|
|
C562
multi-parameter analyser for pH, mV, conductivity,
salinity, TDS, dissolved oxygen and temperature |
 |
1 pH/mV channel
1 conductivity/oxygen channel
1 temperature channel
A high resolution graphic screen with
white backlight shows measurements and temperature.
Full guidance is given by simple instructions on the display in
the language of your choice (English, Dutch, French, German).
Storage memory for 300 measurements.
Shows a GLP report on the screen.
Three year warranty
Robust dust and splash-proof cabinet.
Operates on the mains (120/230 VAC), rechargeable batteries or
9...15 VDC.
Optional 12 V car adaptor permits to work in a car or recharge
the batteries while driving to another site.
Specifications
pH: 0...14 pH
mV: ± 1000 mV
Conductivity: 0...100 mS/cm
Salinity: 0...70 ppt TDS: 0...100
g/l
Dissolved oxygen: 0...20 mg/l,
0...200 %
Temperature: 0...100°C
Resolution: 0.01 pH, 1 mV,
0.1µS/cm, 0.01 mg/l, 1°C |
|
|
download leaflet |
download manual | |
|
|
|
C931
multi-parameter analyser for pH, mV, conductivity,
resistivity, salinity, TDS and temperature |
 |
1 measurement channel
1 temperature channel
A high resolution graphic screen with
white backlight indicates all measurements and operating
parameters such as temperature, date and time.
Multi-point (1...5) calibration of pH electrodes with any of
nine pre-programmed and five user specified standards.
Multi-point (1...3) calibration of conductivity electrodes for
increased linearity with any of three pre-programmed or user
specified standards.
The display guides you at any moment in the language of your
choice (English, Dutch, French, German).
All necessary GLP-procedures are on board.
Password protection prevents any unauthorised access to the
instrument.
Three year warranty.
Storage memory for up to 3600 values + date and time.
Programmable recorder output.
Two-way communication with any computer using RS232.
Robust dust and splash-proof cabinet.
Operates on the mains (120/230 VAC), rechargeable batteries or
9...15 VDC.
Optional 12 V car adaptor permits these laboratory meters to
work in a car.
Optional data acquisition software enables to view, store and
edit the measurements in your computer.
Specifications
pH: -2...+16 pH
mV: ± 2000 mV
Conductivity: 0...2000 mS/cm
Resistivity: 0...200 Mohm.cm
Salinity: 0...70 ppt
TDS: 0...100 g/l
Air pressure: 800...1100 hPa
Temperature: -30...+130°C
Resolution: 0.001 pH, 0.1 mV, 0.001µS/cm, 1 ohm.cm, 0.01
mg/l, 0.1 ppt, 0.1°C |
|
|
download leaflet |
download manual | |
|
|
|
C932
multi-parameter analyser for pH, mV, conductivity,
resistivity, salinity, TDS, dissolved oxygen and temperature |
 |
1 measurement channel
1 temperature channel
A high resolution graphic screen with
white backlight indicates all measurements and operating
parameters such as temperature, date and time.
Multi-point (1...5) calibration of pH electrodes with any of
nine pre-programmed and five user specified standards.
Multi-point (1...3) calibration of conductivity electrodes for
increased linearity with any of three pre-programmed or user
specified standards.
The display guides you at any moment in the language of your
choice (English, Dutch, French, German).
All necessary GLP-procedures are on board.
Operates with a galvanic oxygen electrode requiring no
polarisation time.
Password protection prevents any unauthorised access to the
instrument.
Three year warranty.
Storage memory for up to 3600 values + date and time.
Programmable recorder output.
Two-way communication with any computer using RS232.
Robust dust and splash-proof cabinet.
Operates on the mains (120/230 VAC), rechargeable batteries or
9...15 VDC.
Optional 12 V car adaptor permits these laboratory meters to
work in a car.
Optional data acquisition software enables to view, store and
edit the measurements in your computer.
Specifications
pH: -2...+16 pH
mV: ± 2000 mV
Conductivity: 0...2000 mS/cm
Resistivity: 0...200 Mohm.cm
Salinity: 0...70 ppt
TDS: 0...100 g/l
Dissolved oxygen: 0...60mg/l,
0...600 %
Air pressure: 800...1100 hPa
Temperature: -30...+130°C
Resolution: 0.001 pH, 0.1 mV,
0.001µS/cm, 1 ohm.cm, 0.01 mg/l, 0.1 ppt, 0.1°C |
|
|
download leaflet |
download manual | |
|
|
|
C933
multi-parameter analyser for pH, mV, ion, conductivity,
resistivity, salinity, TDS, dissolved oxygen and temperature |
 |
1 measurement
channel
1 temperature channel
A high resolution graphic screen with
white backlight indicates all measurements and operating
parameters such as temperature, date and time.
Multi-point (1...5) calibration of pH electrodes with any of
nine pre-programmed and five user specified standards.
Multi-point (1...3) calibration of conductivity electrodes for
increased linearity with any of three pre-programmed or user
specified standards.
Two-point calibration + blank correction of ion-selective
electrodes.
The display guides you at any moment in the language of your
choice (English, Dutch, French, German).
All necessary GLP-procedures are on board.
Operates with a galvanic oxygen electrode requiring no
polarisation time.
Password protection prevents any unauthorised access to the
instrument.
Three year warranty.
Storage memory for up to 3600 values + date and time.
Programmable recorder output.
Two-way communication with any computer using RSS232.
Robust dust and splash-proof cabinet.
Operates on the mains (120/230 VAC), rechargeable batteries or
9...15 VDC.
Optional 12 V car adaptor permits these laboratory meters to
work in a car.
Optional data acquisition software enables to view, store and
edit the measurements in your computer.
Specifications
pH: -2...+16 pH
mV: ± 2000 mV
Ion: 10-11...10+1, any unit
Conductivity: 0...2000 mS/cm
Resistivity: 0...200 Mohm.cm
Salinity: 0...70 ppt
TDS: 0...100 g/l
Dissolved oxygen: 0...60mg/l,
0...600 %
Air pressure: 800...1100 hPa
Temperature: -30...+130°C
Resolution: 0.001 pH, 0.1 mV,
0.001µS/cm, 1 ohm.cm, 0.01 mg/l, 0.1 ppt, 0.1°C |
|
|
download leaflet |
download manual | |
|
|
|
K912
analyser for conductivity, resistivity, salinity, TDS and
temperature |
 |
1 conductivity/temperature channel
A high resolution graphic screen with
white backlight indicates all measurements and operating
parameters such as temperature, date and time.
Multi-point (1...3) calibration of conductivity electrodes for
increased linearity with any of three pre-programmed or user
specified standards.
Works with a 4-electrode cell eliminating polarisation effects
and fouling of the conductivity cell.
The display guides you at any moment in the language of your
choice (English, Dutch, French, German).
All necessary GLP-procedures are on board.
Password protection prevents any unauthorised access to the
instrument.
Three year warranty.
Storage memory for up to 3600 values + date and time.
Programmable recorder output.
Two-way communication with any computer using RS232.
Robust dust and splash-proof cabinet.
Operates on the mains (120/230 VAC), rechargeable
batteries or 9...15 VDC.
Optional 12 V car adaptor permits these laboratory meters to
work in a car.
Optional data acquisition software enables to view, store and
edit the measurements in your computer.
Specifications
Conductivity: 0...1000 mS/cm
Resistivity: 0...20 Mohm.cm
TDS: 0...100 g/l
Salinity: 0...70 ppt
Temperature: 0...100°C
Resolution: 0.01µS/cm, 1 ohm.cm, 0.01 mg/l, 0.1 ppt,
0.1°C |
|
|
download leaflet |
download manual | |
|
|